function [FIG,FIG_ENG,battANALOG,ATTIVA] = report_WEL(rWEL,m,NodoWireExtensometerLink,toolrif,...
unitrif,contunit,datarif,Font_caption,Font_tools,battANALOG,ATTIVA,siteID,DT,DT_ENG,...
FIG,FIG_ENG,br,activeEN,status,conn,FileName)
fileID = fopen(FileName,'a');
fmt = '%s \r';
text = 'report_WEL function started';
fprintf(fileID,fmt,text);
import mlreportgen.dom.*
import mlreportgen.report.*
% Make sure DOM is compilable
makeDOMCompilable()
if status(m,1) == 1
if ATTIVA == 1
testo = Paragraph('GMUX non ancora installato o canale inattivo.');
add(DT,testo);
ATTIVA = 0;
if activeEN == 1
testo = Paragraph('GMUX not installed or inactive.');
add(DT_ENG,testo);
end
end
elseif status(m,1) == 3
if ATTIVA == 1
testo = Paragraph(['Monitoraggio completato. Invitiamo a visitare la '...
'piattaforma web per la visione dei dati storici.']);
ATTIVA = 0;
add(DT,testo);
if activeEN == 1
testo = Paragraph(['Monitoring completed. Please log into the web-based platform '...
'to access the complete dataset.']);
add(DT_ENG,testo);
end
end
else
WE = Section();
sezWEL = Heading3('Wire Extensometer Link');
sezWEL.Style = {FontSize(Font_tools),Bold(1),Italic(1)};
WE.Title = sezWEL;
if battANALOG == 0
comando = ['select Date, Time, UnitName, ToolNameID, BatLevel, Temperature from RawDataView where Date >= ''' ...
datarif ''' and UnitName = ''' char(unitrif) ''' and ToolNameID = '''...
char(toolrif) ''' and NodeNum = 1 '];
curs = exec(conn,comando);
curs = fetch(curs);
BatTemp = curs.Data;
[~,cc] = size(BatTemp);
if cc ~= 1 %ci sono dati riferiti all'ultimo mese/periodo di interesse
DataPlot = [BatTemp(:,1) BatTemp(:,2)];
% sistemo date, batteria e temperatura
[rD,~] = size(DataPlot);
T = [cell2mat(DataPlot(:,1)) repmat(' ', [rD,1]) cell2mat(DataPlot(:,2))];
Date = datenum(T);
Batteria = cell2mat(BatTemp(:,5));
Temperatura = cell2mat(BatTemp(:,6));
% testo introduttivo
testoB1 = Paragraph(['I valori di tensione di alimentazione del GMUX durante il periodo '...
'di monitoraggio sono riportati di seguito. Il corretto funzionamento del sistema '...
char(232) ' assicurato per una carica superiore a 12 V. L''ultimo dato disponibile ' char(232) ' pari '...
'a ' num2str(Batteria(end,1)) ' V.']);
testoB2 = Paragraph(['Il GMUX integra al proprio interno un termometro '...
'per monitorate la temperatura di esercizio ed identificare eventuali '...
'anomalie. I dati di temperatura registrati sono riportati di seguito.']);
testoB1.HAlign = 'justify';
testoB2.HAlign = 'justify';
% grafico batteria
figure(19)
plot(Date,Batteria);
hold on
title('Batteria e Temperatura del GMUX');
xlabel('Data [gg/mm/aaaa]');
ylabel('Livello di Batteria [V]');
ylim([floor(min(Batteria(:,1))) ceil(max(Batteria(:,1)))]);
yyaxis right
GMUX = plot(Date,Temperatura,':','LineWidth',1.1);
ylim([floor(min(Temperatura(:,1))) ceil(max(Temperatura(:,1)))]);
ylabel(['Temperatura [' char(176) 'C]']);
set(gca,'YColor','k');
str(1,1) = cellstr('Batteria');
str(2,1) = cellstr('Temperatura');
legend(str,'Location','northwest');
h = gca;
h.XAxis.MinorTick = 'on';
datetick('x','dd/mm/yyyy','keepticks','keeplimits');
xtickangle(20);
grid on
grid minor
xlim([Date(1)-1 Date(end)+1]);
TempName = char(strcat('Report',siteID,'-', contunit,'-GMUX.png'));
saveas(GMUX,TempName);
ChartGMUX = Image(TempName);
ChartGMUX.Style = {Height('8cm'),HAlign('center')};
if Batteria(end,1) >= 12.5
TempName = char(strcat('B_13.jpg'));
elseif Batteria(end,1) >= 12
TempName = char(strcat('B_12.jpg'));
elseif Batteria(end,1) >= 11.3
TempName = char(strcat('B_115.jpg'));
elseif Batteria(end,1) >= 10.5
TempName = char(strcat('B_11.jpg'));
else
TempName = char(strcat('B_10.jpg'));
end
Batt = Image(TempName);
Batt.Style = {Height('4cm'),HAlign('center')};
lot = Table({ChartGMUX, Batt});
lot.TableEntriesStyle = {HAlign('center'),VAlign('middle')};
lot.Style = {ResizeToFitContents(false),Width("100%")};
grps(1) = TableColSpecGroup;
grps(1).Span = 2;
specs(1) = TableColSpec;
specs(1).Span = 1;
specs(1).Style = {Width("80%")};
specs(2) = TableColSpec;
specs(2).Span = 1;
specs(2).Style = {Width("20%")};
grps(1).ColSpecs = specs;
lot.ColSpecGroups = grps;
lot_cap = Paragraph(['Fig. ' num2str(FIG) ' - Livello di carica della batteria e temperatura del '...
'GMUX durante il periodo di riferimento']);
FIG = FIG+1;
lot_cap.Style = {HAlign('center'),FontSize(Font_caption),Italic(1),Color('midnightblue')};
sezBATT = Paragraph('GMUX - Batteria e Temperatura');
sezBATT.Style = {FontSize(Font_tools),Bold(1),Italic(1)};
add(DT,sezBATT);
add(DT,testoB1);
add(DT,testoB2);
add(DT,lot);
add(DT,lot_cap);
add(DT,br);
close(figure(19));
%--ENG---
if activeEN == 1
WE_ENG = Section();
sezWEL_ENG = Heading3('Wire Extensometer Link');
sezWEL_ENG.Style = {OuterMargin('0in','0in','0.15in','0in'),FontSize(Font_tools),Bold(1),Italic(1)};
WE_ENG.Title = sezWEL_ENG;
testoB1 = Paragraph(['The following chart reports the GMUX battery level trend recorded '...
'during the reference time period. '...
'The correct functioning of the data acquisition system is guaranteed for a '...
'minimum level of 12 V. The last available data is equal to ' num2str(Batteria(end,1)) ' V.']);
testoB2 = Paragraph(['GMUX equips also a thermometer that allows the monitoring '...
'of the working temperature and the identification of eventual malfunctioning. The same '...
'chart displays also temperature data recorded by the multiplexer.']);
testoB1.HAlign = 'justify';
testoB2.HAlign = 'justify';
% grafico batteria
figure(19)
plot(Date,Batteria);
hold on
title('GMUX battery level and temperature');
xlabel('Date [dd/mm/yyyy]');
ylabel('Battery Level [V]');
ylim([floor(min(Batteria(:,1))) ceil(max(Batteria(:,1)))]);
yyaxis right
GMUX = plot(Date,Temperatura,':','LineWidth',1.1);
ylim([floor(min(Temperatura(:,1))) ceil(max(Temperatura(:,1)))]);
ylabel(['Temperature [' char(176) 'C]']);
set(gca,'YColor','k');
str(1,1) = cellstr('Battery');
str(2,1) = cellstr('Temperature');
legend(str,'Location','northwest');
h = gca;
h.XAxis.MinorTick = 'on';
datetick('x','dd/mm/yyyy','keepticks','keeplimits');
xtickangle(20);
grid on
grid minor
xlim([Date(1)-1 Date(end)+1]);
TempName = char(strcat('Report',siteID,'-', contunit,'-GMUX_ENG.png'));
saveas(GMUX,TempName);
ChartGMUX = Image(TempName);
ChartGMUX.Style = {Height('8cm'),HAlign('center')};
Batt = Image(TempNameB);
Batt.Style = {Height('4cm'),HAlign('center')};
lot = Table({ChartGMUX, Batt});
lot.TableEntriesStyle = {HAlign('center'),VAlign('middle')};
lot.Style = {ResizeToFitContents(false),Width("100%")};
grps(1) = TableColSpecGroup;
grps(1).Span = 2;
specs(1) = TableColSpec;
specs(1).Span = 1;
specs(1).Style = {Width("80%")};
specs(2) = TableColSpec;
specs(2).Span = 1;
specs(2).Style = {Width("20%")};
grps(1).ColSpecs = specs;
lot.ColSpecGroups = grps;
lot_cap = Paragraph(['Fig. ' num2str(FIG_ENG) ' - Battery level and temperature recorded '...
'by the GMUX during the reference time period']);
FIG_ENG = FIG_ENG+1;
lot_cap.Style = {HAlign('center'),FontSize(Font_caption),Italic(1),Color('midnightblue')};
Batt_ENG = Section();
sezBATT_ENG = Heading3('GMUX - Battery and temperature');
sezBATT_ENG.Style = {FontSize(Font_tools),Bold(1),Italic(1)};
Batt_ENG.Title = sezBATT_ENG;
add(DT_ENG,sezBATT_ENG);
add(DT_ENG,testoB1);
add(DT_ENG,testoB2);
add(DT_ENG,lot);
add(DT_ENG,lot_cap);
add(DT_ENG,br);
close(figure(19));
end
battANALOG = 1;
end
end
add(DT,sezWEL);
if activeEN == 1
add(DT_ENG,sezWEL_ENG);
end
for w = 1:rWEL(m,1)
NodeNum = num2str(NodoWireExtensometerLink(w,m));
comando = ['select EventDate, EventTime, XShift, T_node from ElabDataView where EventDate >= ''' ...
datarif ''' and ToolNameID = ''' char(toolrif) ''' and UnitName = ''' char(unitrif) ...
''' and NodeNum = ''' NodeNum ''' '];
curs = exec(conn,comando);
curs = fetch(curs);
Dati = curs.Data;
% Modifico il formato di data e ora
[rD,rC] = size(Dati);
if rC ~= 1
T = [cell2mat(Dati(:,1)) repmat(' ', [rD,1]) cell2mat(Dati(:,2))];
Date = datenum(T); % Data
allungamento = cell2mat(Dati(:,3)); % allungamento filo
var_X = allungamento - allungamento(1,:);
TempWEL = cell2mat(Dati(:,4)); % temperatura
% grafico allungamento NELL'ULTIMO MESE
figure(10);
if isnan(TempWEL(1)) == 0
yyaxis left
end
wire = plot(Date,var_X);
control = max(abs(var_X));
if control < 1 % mm
ylim([-1 1]);
end
hold on
xlabel('Data [gg/mm/aaaa]');
ylabel('Allungamento (+) / Accorciamento (-) [mm]');
set(gca,'YColor','k');
if isnan(TempWEL(1)) == 0
yyaxis right
plot(Date,TempWEL,':','LineWidth',1.1);
ylabel(['Temperatura [' char(176) 'C]']);
set(gca,'YColor','k');
str(1,1) = cellstr('Variazione lunghezza filo');
str(2,1) = cellstr('Temperatura');
MX(1) = max(TempWEL(1:10));
MX(2) = min(TempWEL(1:10));
MAX = max(abs(MX));
IN = find(abs(MX)==MAX);
if IN == 1 % Legenda sotto
legend(str,'Location','southwest');
else
legend(str,'Location','northwest');
end
end
title(['Allungamento/accorciamento del filo del nodo numero ' NodeNum]);
h = gca;
h.XAxis.MinorTick = 'on';
datetick('x','dd/mm/yyyy','keepticks','keeplimits');
xtickangle(20);
grid on
grid minor
TempName = char(strcat('Report',siteID,'-', char(toolrif),'-WireExt', NodeNum, '.png'));
saveas(wire,TempName);
ChartWEL = Image(TempName);
ChartWEL.Style = {Height('7.3cm'),HAlign('center')};
ChartWEL_cap = Paragraph(['Fig. ' num2str(FIG) ' - Variazione di lunghezza '...
'registrata dall''estensimetro numero ' NodeNum ', '...
'durante il periodo temporale di riferimento']);
FIG = FIG+1;
ChartWEL_cap.Style = {HAlign('center'),FontSize(Font_caption),Italic(1),Color('midnightblue')};
testo = Paragraph(['I grafici seguenti rappresentano i dati relativi '...
'alla variazione di lunghezza registrata dagli estensimetri a filo '...
'collegati all''Analog Array. In particolare, valori positivi indicano '...
'un allungamento, mentre numeri negativi rilevano un accorciamento.']);
testo2 = Paragraph(['Durante il periodo temporale di riferimento, '...
'il nodo numero ' NodeNum ' ha registrato valori massimi e minimi di lunghezza rispettivamente pari a '...
num2str(round(max(var_X),2), '%0.2f') ' mm e ' num2str(round(min(var_X),2), '%0.2f')...
' mm, con una variazione di circa '...
num2str(round(max(var_X),2)-round(min(var_X),2),'%0.2f') ' mm.' ]);
testo.HAlign = 'justify';
testo2.HAlign = 'justify';
if w == 1
add(DT,testo);
end
add(DT,testo2);
add(DT,ChartWEL);
add(DT,ChartWEL_cap);
if w == rWEL(m,1)
add(DT,br);
end
close(figure(10));
%--ENG--
if activeEN == 1
% grafico allungamento NELL'ULTIMO MESE
figure(20);
if isnan(TempWEL(1)) == 0
yyaxis left
end
wire = plot(Date,var_X);
control = max(abs(var_X));
if control < 1 % mm
ylim([-1 1]);
end
hold on
xlabel('Date [dd/mm/yyyy]');
ylabel('Wire length increase (+) / decrease (-) [mm]');
set(gca,'YColor','k');
if isnan(TempWEL(1)) == 0
yyaxis right
plot(Date,TempWEL,':','LineWidth',1.1);
ylabel(['Temperature [' char(176) 'C]']);
set(gca,'YColor','k');
str(1,1) = cellstr('Wire length variation');
str(2,1) = cellstr('Temperature');
MX(1) = max(TempWEL(1:10));
MX(2) = min(TempWEL(1:10));
MAX = max(abs(MX));
IN = find(abs(MX)==MAX);
if IN == 1 % Legenda sotto
legend(str,'Location','southwest');
else
legend(str,'Location','northwest');
end
end
title(['Wire length increase/decrease, node ' NodeNum]);
h = gca;
h.XAxis.MinorTick = 'on';
datetick('x','dd/mm/yyyy','keepticks','keeplimits');
xtickangle(20);
grid on
grid minor
TempName = char(strcat('Report',siteID,'-', char(toolrif),'-WireExt', NodeNum, '_ENG.png'));
saveas(wire,TempName);
ChartWEL_ENG = Image(TempName);
ChartWEL_ENG.Style = {Height('7.3cm'),HAlign('center')};
ChartWEL_ENG_cap = Paragraph(['Fig. ' num2str(FIG_ENG) ' - Wire length variation '...
'recorded by extensometer ' NodeNum ' '...
'during the reference time period']);
FIG_ENG = FIG_ENG+1;
ChartWEL_ENG_cap.Style = {HAlign('center'),FontSize(Font_caption),Italic(1),Color('midnightblue')};
testo = Paragraph(['The following graphs display the wire length variation '...
'recorded by wire extensometer sensors integrated in the '...
'Analog Array. In particular, positive values represent a incresase of the '...
'wire length, while negative values indicate a shortening of the wire length.']);
testo2 = Paragraph(['During the reference time period, '...
'node ' NodeNum ' recorded maximum and minimum values of wire length equal to '...
num2str(round(max(var_X),2), '%0.2f') ' mm and ' num2str(round(min(var_X),2), '%0.2f')...
' mm respectively, corresponding to a length variation of '...
num2str(round(max(var_X),2)-round(min(var_X),2),'%0.2f') ' mm.' ]);
testo.HAlign = 'justify';
testo2.HAlign = 'justify';
if w == 1
add(DT_ENG,testo);
end
add(DT_ENG,testo2);
add(DT_ENG,ChartWEL_ENG);
add(DT_ENG,ChartWEL_ENG_cap);
if w == rWEL(m,1)
add(DT_ENG,br);
end
close(figure(20));
end
% pulisco variabili da riutilizzare per catena successiva
clear allungamento;
else
if ATTIVA == 1
testo = Paragraph('Non sono presenti dati relativi al periodo temporale considerato.');
ATTIVA = 0;
add(DT,testo);
if activeEN == 1
testo = Paragraph('No data available for the reference time period.');
add(DT_ENG,testo);
end
end
end
end
end
text = 'report_WEL function executed correctly';
fprintf(fileID,fmt,text);
fclose(fileID);
end