function [FIG,FIG_ENG,battANALOG,ATTIVA] = report_PT100(rPT100,m,NodoPT100Link,... toolrif,unitrif,datarif,Font_caption,Font_tools,siteID,DT,DT_ENG,FIG,FIG_ENG,... battANALOG,ATTIVA,activeEN,contunit,br,status,conn,FileName) fileID = fopen(FileName,'a'); fmt = '%s \r'; text = 'report_PT100 function started'; fprintf(fileID,fmt,text); import mlreportgen.dom.* import mlreportgen.report.* % Make sure DOM is compilable makeDOMCompilable() if status(m,1) == 1 if ATTIVA == 1 ATTIVA = 0; testo = Paragraph('GMUX non ancora installato o canale inattivo.'); add(DT,testo); if activeEN == 1 testo = Paragraph('GMUX not installed or inactive.'); add(DT_ENG,testo); end end elseif status(m,1) == 3 if ATTIVA == 1 ATTIVA = 0; testo = Paragraph(['Monitoraggio completato. Invitiamo a visitare la '... 'piattaforma web per la visione dei dati storici.']); add(DT,testo); if activeEN == 1 testo = Paragraph(['Monitoring completed. Please log into the web-based platform '... 'to access the complete dataset.']); add(DT_ENG,testo); end end else PTE = Section(); titolo = 1; if battANALOG == 0 comando = ['select Date, Time, UnitName, ToolNameID, BatLevel, Temperature from RawDataView where Date >= ''' ... datarif ''' and UnitName = ''' char(unitrif) ''' and ToolNameID = '''... char(toolrif) ''' and NodeNum = 1 ']; curs = exec(conn,comando); curs = fetch(curs); BatTemp = curs.Data; [~,cc] = size(BatTemp); if cc ~= 1 %ci sono dati riferiti all'ultimo mese/periodo di interesse DataPlot = [BatTemp(:,1) BatTemp(:,2)]; % sistemo date, batteria e temperatura [rD,~] = size(DataPlot); T = [cell2mat(DataPlot(:,1)) repmat(' ', [rD,1]) cell2mat(DataPlot(:,2))]; Date = datenum(T); Batteria = cell2mat(BatTemp(:,5)); Temperatura = cell2mat(BatTemp(:,6)); % testo introduttivo testoB1 = Paragraph(['I valori di tensione di alimentazione del GMUX durante il periodo '... 'di monitoraggio sono riportati di seguito. Il corretto funzionamento del sistema '... char(232) ' assicurato per una carica superiore a 12 V. L''ultimo dato disponibile ' char(232) ' pari '... 'a ' num2str(Batteria(end,1)) ' V.']); testoB2 = Paragraph(['Il GMUX integra al proprio interno un termometro '... 'per monitorate la temperatura di esercizio ed identificare eventuali '... 'anomalie. I dati di temperatura registrati sono riportati di seguito.']); testoB1.HAlign = 'justify'; testoB2.HAlign = 'justify'; % grafico batteria figure(19) plot(Date,Batteria); hold on title('Batteria e Temperatura del GMUX'); xlabel('Data [gg/mm/aaaa]'); ylabel('Livello di Batteria [V]'); ylim([floor(min(Batteria(:,1))) ceil(max(Batteria(:,1)))]); yyaxis right GMUX = plot(Date,Temperatura,':','LineWidth',1.1); ylim([floor(min(Temperatura(:,1))) ceil(max(Temperatura(:,1)))]); ylabel(['Temperatura [' char(176) 'C]']); set(gca,'YColor','k'); str(1,1) = cellstr('Batteria'); str(2,1) = cellstr('Temperatura'); legend(str,'Location','northwest'); h = gca; h.XAxis.MinorTick = 'on'; datetick('x','dd/mm/yyyy','keepticks','keeplimits'); xtickangle(20); grid on grid minor xlim([Date(1)-1 Date(end)+1]); TempName = char(strcat('Report',siteID,'-', contunit,'-GMUX.png')); saveas(GMUX,TempName); ChartGMUX = Image(TempName); ChartGMUX.Style = {Height('8cm'),HAlign('center')}; if Batteria(end,1) >= 12.5 TempName = char(strcat('B_13.jpg')); elseif Batteria(end,1) >= 12 TempName = char(strcat('B_12.jpg')); elseif Batteria(end,1) >= 11.3 TempName = char(strcat('B_115.jpg')); elseif Batteria(end,1) >= 10.5 TempName = char(strcat('B_11.jpg')); else TempName = char(strcat('B_10.jpg')); end Batt = Image(TempName); Batt.Style = {Height('4cm'),HAlign('center')}; lot = Table({ChartGMUX, Batt}); lot.TableEntriesStyle = {HAlign('center'),VAlign('middle')}; lot.Style = {ResizeToFitContents(false),Width("100%")}; grps(1) = TableColSpecGroup; grps(1).Span = 2; specs(1) = TableColSpec; specs(1).Span = 1; specs(1).Style = {Width("80%")}; specs(2) = TableColSpec; specs(2).Span = 1; specs(2).Style = {Width("20%")}; grps(1).ColSpecs = specs; lot.ColSpecGroups = grps; lot_cap = Paragraph(['Fig. ' num2str(FIG) ' - Livello di carica della batteria e temperatura del '... 'GMUX durante il periodo di riferimento']); FIG = FIG+1; lot_cap.Style = {HAlign('center'),FontSize(Font_caption),Italic(1),Color('midnightblue')}; FIG = FIG+1; Chart_cap.Style = {HAlign('center'),FontSize(Font_caption),Italic(1),Color('midnightblue')}; sezBATT = Paragraph('GMUX - Batteria e Temperatura'); sezBATT.Style = {FontSize(Font_tools),Bold(1),Italic(1)}; add(DT,sezBATT); add(DT,testoB1); add(DT,testoB2); add(DT,lot); add(DT,lot_cap); add(DT,br); close(figure(19)); if activeEN == 1 testoB1 = Paragraph(['The following chart reports the GMUX battery level trend recorded '... 'during the reference time period. '... 'The correct functioning of the data acquisition system is guaranteed for a '... 'minimum level of 12 V. The last available data is equal to ' num2str(Batteria(end,1)) ' V.']); testoB2 = Paragraph(['GMUX equips also a thermometer that allows the monitoring '... 'of the working temperature and the identification of eventual malfunctioning. The same '... 'chart displays also temperature data recorded by the multiplexer.']); testoB1.HAlign = 'justify'; testoB2.HAlign = 'justify'; % grafico batteria figure(19) plot(Date,Batteria); hold on title('GMUX battery level and temperature'); xlabel('Date [dd/mm/yyyy]'); ylabel('Battery Level [V]'); ylim([floor(min(Batteria(:,1))) ceil(max(Batteria(:,1)))]); yyaxis right GMUX = plot(Date,Temperatura,':','LineWidth',1.1); ylim([floor(min(Temperatura(:,1))) ceil(max(Temperatura(:,1)))]); ylabel(['Temperature [' char(176) 'C]']); set(gca,'YColor','k'); str(1,1) = cellstr('Battery'); str(2,1) = cellstr('Temperature'); legend(str,'Location','northwest'); h = gca; h.XAxis.MinorTick = 'on'; datetick('x','dd/mm/yyyy','keepticks','keeplimits'); xtickangle(20); grid on grid minor xlim([Date(1)-1 Date(end)+1]); TempName = char(strcat('Report',siteID,'-', contunit,'-GMUX_ENG.png')); saveas(GMUX,TempName); ChartGMUX = Image(TempName); ChartGMUX.Style = {Height('8cm'),HAlign('center')}; Batt = Image(TempNameB); Batt.Style = {Height('4cm'),HAlign('center')}; lot = Table({ChartGMUX, Batt}); lot.TableEntriesStyle = {HAlign('center'),VAlign('middle')}; lot.Style = {ResizeToFitContents(false),Width("100%")}; grps(1) = TableColSpecGroup; grps(1).Span = 2; specs(1) = TableColSpec; specs(1).Span = 1; specs(1).Style = {Width("80%")}; specs(2) = TableColSpec; specs(2).Span = 1; specs(2).Style = {Width("20%")}; grps(1).ColSpecs = specs; lot.ColSpecGroups = grps; lot_cap = Paragraph(['Fig. ' num2str(FIG_ENG) ' - Battery level and temperature recorded '... 'by the GMUX during the reference time period']); FIG_ENG = FIG_ENG+1; lot_cap.Style = {HAlign('center'),FontSize(Font_caption),Italic(1),Color('midnightblue')}; Batt_ENG = Section(); sezBATT_ENG = Heading3('GMUX - Battery and temperature'); sezBATT_ENG.Style = {FontSize(Font_tools),Bold(1),Italic(1)}; Batt_ENG.Title = sezBATT_ENG; add(DT_ENG,sezBATT_ENG); add(DT_ENG,testoB1); add(DT_ENG,testoB2); add(DT_ENG,lot); add(DT_ENG,lot_cap); add(DT_ENG,br); close(figure(19)); end battANALOG = 1; end end for n = 1:rPT100(m,1) NodeNum = num2str(NodoPT100Link(n,m)); comando = ['select EventDate, EventTime, T_node from ElabDataView where EventDate >= ''' ... datarif ''' and ToolNameID = ''' char(toolrif) ''' and UnitName = ''' char(unitrif) ... ''' and NodeNum = ''' NodeNum ''' ']; curs = exec(conn,comando); curs = fetch(curs); Dati = curs.Data; % Modifico il formato di data e ora [rD,rC] = size(Dati); if rC ~= 1 T = [cell2mat(Dati(:,1)) repmat(' ', [rD,1]) cell2mat(Dati(:,2))]; Date = datenum(T); % Data TempPT100 = cell2mat(Dati(:,3)); % temperatura MaxTempPT100 = max(TempPT100); MinTempPT100 = min(TempPT100); % grafico temperatura figure(1) graficoPT100 = plot(Date,TempPT100); xlim([Date(1)-1 Date(end)+1]); title(['Andamento della temperatura registrata dal sensore numero ' NodeNum ]); xlabel('Data [gg/mm/aaaa]'); ylabel(['Temperatura [' char(176) 'C]']); h = gca; h.XAxis.MinorTick = 'on'; datetick('x','dd/mm/yyyy','keepticks','keeplimits'); xtickangle(20); grid on grid minor TempName = char(strcat('Report',siteID,'-', char(toolrif),'PT100_',NodeNum,'.png')); if titolo == 1 sezPT100 = Heading3('PT100 Link'); sezPT100.Style = {OuterMargin('0in','0in','0.15in','0in'),FontSize(Font_tools),Bold(1),Italic(1)}; PTE.Title = sezPT100; add(DT,sezPT100); if activeEN == 0 titolo = 0; end end saveas(graficoPT100,TempName); ChartPT100 = Image(TempName); ChartPT100.Style = {Height('7.3cm'),HAlign('center')}; ChartPT100_cap = Paragraph(['Fig. ' num2str(FIG) ' - Andamento della'... ' temperatura misurata dalla sonda PT100 numero ' NodeNum... ' durante il periodo temporale di riferimento']); FIG = FIG+1; ChartPT100_cap.Style = {HAlign('justify'),FontSize(Font_caption),Italic(1),Color('midnightblue')}; testo = Paragraph(['I grafici seguenti mostrano i valori di temperatura '... 'misurati dalle sonde PT100 collegato all''Analog Array.']); testo2 = Paragraph(['Durante il periodo temporale di riferimento, il nodo '... 'numero ' NodeNum ' ha registrato valori massimi e minimi di temperatura rispettivamente pari '... 'a ' num2str(MaxTempPT100,'%0.1f') '' char(176) 'C e ' num2str(MinTempPT100,'%0.1f') '' char(176) 'C.']); testo.HAlign = 'justify'; if n == 1 add(DT,testo); end add(DT,testo2); add(DT,ChartPT100); add(DT,ChartPT100_cap); if n == rPT100(m,1) add(DT,br); end close(figure(1)); if activeEN == 1 % grafico temperatura figure(1) graficoPT100 = plot(Date,TempPT100); xlim([Date(1)-1 Date(end)+1]); title(['Temperature recorded by sensor no. ' NodeNum ]); xlabel('Date [dd/mm/yyyy]'); ylabel(['Temperature [' char(176) 'C]']); h = gca; h.XAxis.MinorTick = 'on'; datetick('x','dd/mm/yyyy','keepticks','keeplimits'); xtickangle(20); grid on grid minor TempName = char(strcat('Report',siteID,'-', char(toolrif),'PT100_',NodeNum,'_ENG.png')); if titolo == 1 sezPT100 = Heading3('PT100 Link'); sezPT100.Style = {OuterMargin('0in','0in','0.15in','0in'),FontSize(Font_tools),Bold(1),Italic(1)}; PTE.Title = sezPT100; add(DT,sezPT100); titolo = 0; end saveas(graficoPT100,TempName); ChartPT100 = Image(TempName); ChartPT100.Style = {Height('7.3cm'),HAlign('center')}; ChartPT100_cap = Paragraph(['Fig. ' num2str(FIG_ENG) ' - Time evolution of '... ' the temperature recorded by PT100 sensor number ' NodeNum... ' during the reference time period']); FIG_ENG = FIG_ENG+1; ChartPT100_cap.Style = {HAlign('justify'),FontSize(Font_caption),Italic(1),Color('midnightblue')}; testo = Paragraph(['The following graphs show the temperature values '... 'recorded by PT100 sensors.']); testo2 = Paragraph(['During the reference time period, node number '... NodeNum ' highlighted maximum and minimum temperature values equal to '... num2str(MaxTempPT100,'%0.1f') '' char(176) 'C and ' num2str(MinTempPT100,'%0.1f') '' char(176) 'C respectively.']); testo.HAlign = 'justify'; if n == 1 add(DT_ENG,testo); end add(DT_ENG,testo2); add(DT_ENG,ChartPT100); add(DT_ENG,ChartPT100_cap); if n == rPT100(m,1) add(DT_ENG,br); end close(figure(1)); end %pulisco variabili da riutilizzare per catena successiva clear TempPT100; clear MaxTempPT100; clear MinTempPT100; else if ATTIVA == 1 ATTIVA = 0; testo = Paragraph('Non sono presenti dati relativi al periodo temporale considerato.'); add(DT,testo); if activeEN == 1 testo = Paragraph('No data available for the reference time period.'); add(DT_ENG,testo); if m == 1 add(DT_ENG,br); end end end end end end text = 'report_PT100 function executed correctly'; fprintf(fileID,fmt,text); fclose(fileID); end