Sync from remote server: 2025-10-12 18:56:41

This commit is contained in:
2025-10-12 18:56:59 +02:00
commit 7e8ee264aa
553 changed files with 161447 additions and 0 deletions

365
ATD/report_PrL.m Executable file
View File

@@ -0,0 +1,365 @@
function [FIG,FIG_ENG,battANALOG,ATTIVA] = report_PrL(rPrL,m,NodoPressureLink,toolrif,...
unitrif,datarif,Font_caption,Font_tools,siteID,DT,DT_ENG,FIG,FIG_ENG,br,status,ATTIVA,...
battANALOG,activeEN,conn,FileName)
fileID = fopen(FileName,'a');
fmt = '%s \r';
text = 'report_PrL function started';
fprintf(fileID,fmt,text);
import mlreportgen.dom.*
import mlreportgen.report.*
% Make sure DOM is compilable
makeDOMCompilable()
if status(m,1) == 1
if ATTIVA == 1
ATTIVA = 0;
testo = Paragraph('GMUX non ancora installato o canale inattivo.');
add(DT,testo);
if activeEN == 1
testo = Paragraph('GMUX not installed or inactive.');
add(DT_ENG,testo);
end
end
elseif status(m,1) == 3
if ATTIVA == 1
ATTIVA = 0;
testo = Paragraph(['Monitoraggio completato. Invitiamo a visitare la '...
'piattaforma web per la visione dei dati storici.']);
add(DT,testo);
if activeEN == 1
testo = Paragraph('Array not installed or inactive.');
add(DT_ENG,testo);
end
end
else
if battANALOG == 0
comando = ['select Date, Time, UnitName, ToolNameID, BatLevel, Temperature from RawDataView where Date >= ''' ...
datarif ''' and UnitName = ''' char(unitrif) ''' and ToolNameID = '''...
char(toolrif) ''' and NodeNum = 1 '];
curs = exec(conn,comando);
curs = fetch(curs);
BatTemp = curs.Data;
[~,cc] = size(BatTemp);
if cc ~= 1 %ci sono dati riferiti all'ultimo mese/periodo di interesse
DataPlot = [BatTemp(:,1) BatTemp(:,2)];
% sistemo date, batteria e temperatura
[rD,~] = size(DataPlot);
T = [cell2mat(DataPlot(:,1)) repmat(' ', [rD,1]) cell2mat(DataPlot(:,2))];
Date = datenum(T);
Batteria = cell2mat(BatTemp(:,5));
Temperatura = cell2mat(BatTemp(:,6));
% testo introduttivo
testoB1 = Paragraph(['I valori di tensione di alimentazione del GMUX registrati durante il periodo '...
'di monitoraggio sono riportati di seguito. Il corretto funzionamento del sistema '...
char(232) ' assicurato per una carica superiore a 12 V. L''ultimo dato disponibile ' char(232) ' pari '...
'a ' num2str(Batteria(end,1)) ' V.']);
testoB2 = Paragraph(['Il GMUX integra al proprio interno un termometro '...
'per monitorate la temperatura di esercizio ed identificare eventuali '...
'anomalie. I dati di temperatura registrati sono riportati di seguito.']);
testoB1.HAlign = 'justify';
testoB2.HAlign = 'justify';
% grafico batteria
figure(19)
plot(Date,Batteria);
hold on
title('Batteria e Temperatura del GMUX');
xlabel('Data [gg/mm/aaaa]');
ylabel('Livello di Batteria [V]');
ylim([floor(min(Batteria(:,1))) ceil(max(Batteria(:,1)))]);
yyaxis right
GMUX = plot(Date,Temperatura,':','LineWidth',1.1);
ylim([floor(min(Temperatura(:,1))) ceil(max(Temperatura(:,1)))]);
ylabel(['Temperatura [' char(176) 'C]']);
set(gca,'YColor','k');
str(1,1) = cellstr('Batteria');
str(2,1) = cellstr('Temperatura');
legend(str,'Location','northwest');
h = gca;
h.XAxis.MinorTick = 'on';
datetick('x','dd/mm/yyyy','keepticks','keeplimits');
xtickangle(20);
grid on
grid minor
xlim([Date(1)-1 Date(end)+1]);
TempName = char(strcat('Report',siteID,'-', contunit,'-GMUX.png'));
saveas(GMUX,TempName);
ChartGMUX = Image(TempName);
ChartGMUX.Style = {Height('8cm'),HAlign('center')};
if Batteria(end,1) >= 12.5
TempName = char(strcat('B_13.jpg'));
elseif Batteria(end,1) >= 12
TempName = char(strcat('B_12.jpg'));
elseif Batteria(end,1) >= 11.3
TempName = char(strcat('B_115.jpg'));
elseif Batteria(end,1) >= 10.5
TempName = char(strcat('B_11.jpg'));
else
TempName = char(strcat('B_10.jpg'));
end
Batt = Image(TempNameB);
Batt.Style = {Height('4cm'),HAlign('center')};
lot = Table({ChartGMUX, Batt});
lot.TableEntriesStyle = {HAlign('center'),VAlign('middle')};
lot.Style = {ResizeToFitContents(false),Width("100%")};
grps(1) = TableColSpecGroup;
grps(1).Span = 2;
specs(1) = TableColSpec;
specs(1).Span = 1;
specs(1).Style = {Width("80%")};
specs(2) = TableColSpec;
specs(2).Span = 1;
specs(2).Style = {Width("20%")};
grps(1).ColSpecs = specs;
lot.ColSpecGroups = grps;
lot_cap = Paragraph(['Fig. ' num2str(FIG) ' - Livello di carica della batteria e temperatura del '...
'GMUX registrati durante il periodo di riferimento']);
FIG = FIG+1;
lot_cap.Style = {HAlign('center'),FontSize(Font_caption),Italic(1),Color('midnightblue')};
Batt = Section();
sezBATT = Heading3('GMUX - Batteria e Temperatura');
sezBATT.Style = {FontSize(Font_tools),Bold(1),Italic(1)};
Batt.Title = sezBATT;
add(DT,sezBATT);
add(DT,testoB1);
add(DT,testoB2);
add(DT,lot);
add(DT,lot_cap);
add(DT,br);
close(figure(19));
if activeEN == 1
testoB1 = Paragraph(['The following chart reports the GMUX battery level trend recorded '...
'during the reference time period. '...
'The correct functioning of the data acquisition system is guaranteed for a '...
'minimum level of 12 V. The last available data is equal to ' num2str(Batteria(end,1)) ' V.']);
testoB2 = Paragraph(['GMUX equips also a thermometer that allows the monitoring '...
'of the working temperature and the identification of eventual malfunctioning. The same '...
'chart displays also temperature data recorded by the multiplexer.']);
testoB1.HAlign = 'justify';
testoB2.HAlign = 'justify';
% grafico batteria
figure(19)
plot(Date,Batteria);
hold on
title('GMUX battery level and temperature');
xlabel('Date [dd/mm/yyyy]');
ylabel('Battery Level [V]');
ylim([floor(min(Batteria(:,1))) ceil(max(Batteria(:,1)))]);
yyaxis right
GMUX = plot(Date,Temperatura,':','LineWidth',1.1);
ylim([floor(min(Temperatura(:,1))) ceil(max(Temperatura(:,1)))]);
ylabel(['Temperature [' char(176) 'C]']);
set(gca,'YColor','k');
str(1,1) = cellstr('Battery');
str(2,1) = cellstr('Temperature');
legend(str,'Location','northwest');
h = gca;
h.XAxis.MinorTick = 'on';
datetick('x','dd/mm/yyyy','keepticks','keeplimits');
xtickangle(20);
grid on
grid minor
xlim([Date(1)-1 Date(end)+1]);
TempName = char(strcat('Report',siteID,'-', contunit,'-GMUX_ENG.png'));
saveas(GMUX,TempName);
ChartGMUX = Image(TempName);
ChartGMUX.Style = {Height('8cm'),HAlign('center')};
Batt = Image(TempNameB);
Batt.Style = {Height('4cm'),HAlign('center')};
lot = Table({ChartGMUX, Batt});
lot.TableEntriesStyle = {HAlign('center'),VAlign('middle')};
lot.Style = {ResizeToFitContents(false),Width("100%")};
grps(1) = TableColSpecGroup;
grps(1).Span = 2;
specs(1) = TableColSpec;
specs(1).Span = 1;
specs(1).Style = {Width("80%")};
specs(2) = TableColSpec;
specs(2).Span = 1;
specs(2).Style = {Width("20%")};
grps(1).ColSpecs = specs;
lot.ColSpecGroups = grps;
lot_cap = Paragraph(['Fig. ' num2str(FIG_ENG) ' - Battery level and temperature recorded '...
'by the GMUX during the reference time period']);
FIG_ENG = FIG_ENG+1;
lot_cap.Style = {HAlign('center'),FontSize(Font_caption),Italic(1),Color('midnightblue')};
Batt_ENG = Section();
sezBATT_ENG = Heading3('GMUX - Battery and temperature');
sezBATT_ENG.Style = {FontSize(Font_tools),Bold(1),Italic(1)};
Batt_ENG.Title = sezBATT_ENG;
add(DT_ENG,sezBATT_ENG);
add(DT_ENG,testoB1);
add(DT_ENG,testoB2);
add(DT_ENG,lot);
add(DT_ENG,lot_cap);
add(DT_ENG,br);
close(figure(19));
end
battANALOG = 1;
end
end
sezPrL = Heading3('Pressure Link');
sezPrL.Style = {FontSize(Font_tools),Bold(1),Italic(1)};
PR = Section();
PR.Title = sezPrL;
add(DT,sezPrL);
if activeEN == 1
add(DT_ENG,sezPrL);
end
for ld = 1:rPrL(m,1)
NodeNum = num2str(NodoPressureLink(ld,m));
comando = ['select EventDate, EventTime, pressure from ElabDataView where EventDate >= ''' ...
datarif ''' and ToolNameID = ''' char(toolrif) ''' and UnitName = ''' char(unitrif) ...
''' and NodeNum = ''' NodeNum ''' '];
curs = exec(conn,comando);
curs = fetch(curs);
Dati = curs.Data;
% Modifico il formato di data e ora
[rD,rC] = size(Dati);
if rC ~= 1
T = [cell2mat(Dati(:,1)) repmat(' ', [rD,1]) cell2mat(Dati(:,2))];
Date = datenum(T); % Data
pressione = cell2mat(Dati(:,3)); % carico cella
var_pressione = pressione-pressione(1); % variazione carico
% grafico carico
figure(5);
load = plot(Date,var_pressione);
title(['Variazione di Pressione - Nodo numero ' NodeNum '']);
xlabel('Data [gg/mm/aaaa]');
ylabel('Variazione di pressione [kPa]');
if max(var_pressione) < 20 && min(var_pressione) > -20
ylim([-20 20]);
elseif max(var_pressione) > 20 && min(var_pressione) > -20
ylim([-20 inf]);
elseif max(var_pressione) < 20 && min(var_pressione) < -20
ylim([-inf 20]);
end
h = gca;
h.XAxis.MinorTick = 'on';
datetick('x','dd/mm/yyyy','keepticks','keeplimits');
xtickangle(20);
grid on
grid minor
hold off
TempName = char(strcat('Report',siteID,'-', char(toolrif),'-CellaPressione', NodeNum, '.png'));
saveas(load,TempName);
ChartPrL = Image(TempName);
ChartPrL.Style = {Height('7.3cm'),HAlign('center')};
ChartPrL_cap = Paragraph(['Fig. ' num2str(FIG) ' - Variazione di pressione'...
' registrata dalla cella, nodo numero ' NodeNum...
', nel periodo temporale di riferimento']);
FIG = FIG+1;
ChartPrL_cap.Style = {HAlign('center'),FontSize(Font_caption),Italic(1),Color('midnightblue')};
testo = Paragraph(['I grafici seguenti rappresentato i dati relativi '...
'alla variazione di pressione (in kPa) rilevata dai sensori collegati all''Analog Array.']);
testo2 = Paragraph(['Durante il periodo temporale di riferimento, il nodo numero ' NodeNum...
' ha registrato una massima variazione di pressione pari a '...
num2str(round(max(abs(var_pressione)),2), '%0.2f') ' kPa, mentre il massimo '...
'valore di pressione assoluta ' char(232) ' pari a ' num2str(round(max(pressione),2), '%0.2f') ' kPa.' ]);
testo.HAlign = 'justify';
testo2.HAlign = 'justify';
if ld == 1
add(DT,testo);
end
add(DT,testo2);
add(DT,ChartPrL);
add(DT,ChartPrL_cap);
if ld == rPrL(m,1)
add(DT,br);
end
close(figure(5));
if activeEN == 1
% grafico carico
figure(5);
load = plot(Date,var_pressione);
title(['Pressure variation - Node number ' NodeNum '']);
xlabel('Date [dd/mm/yyyy]');
ylabel('Pressure variation [kPa]');
if max(var_pressione) < 20 && min(var_pressione) > -20
ylim([-20 20]);
elseif max(var_pressione) > 20 && min(var_pressione) > -20
ylim([-20 inf]);
elseif max(var_pressione) < 20 && min(var_pressione) < -20
ylim([-inf 20]);
end
h = gca;
h.XAxis.MinorTick = 'on';
datetick('x','dd/mm/yyyy','keepticks','keeplimits');
xtickangle(20);
grid on
grid minor
hold off
TempName = char(strcat('Report',siteID,'-', char(toolrif),'-CellaPressione', NodeNum, '_ENG.png'));
saveas(load,TempName);
ChartPrL = Image(TempName);
ChartPrL.Style = {Height('7.3cm'),HAlign('center')};
ChartPrL_cap = Paragraph(['Fig. ' num2str(FIG_ENG) ' - Pressure variation '...
'recorded by the pressure cell, node number ' NodeNum...
', during the reference time period']);
FIG_ENG = FIG_ENG+1;
ChartPrL_cap.Style = {HAlign('center'),FontSize(Font_caption),Italic(1),Color('midnightblue')};
testo = Paragraph(['The following representations show the pressure variation recorded by '...
'the sensors that equip the Analog Array.']);
testo2 = Paragraph(['During the reference monitoring period, node number ' NodeNum...
' recorded a maximum pressure variation of '...
num2str(round(max(abs(var_pressione)),2), '%0.2f') ' kPa, while the maximum absolute '...
'pressure value is ' num2str(round(max(pressione),2), '%0.2f') ' kPa.' ]);
testo.HAlign = 'justify';
testo2.HAlign = 'justify';
if ld == 1
add(DT_ENG,testo);
end
add(DT_ENG,testo2);
add(DT_ENG,ChartPrL);
add(DT_ENG,ChartPrL_cap);
if ld == rPrL(m,1)
add(DT_ENG,br);
end
close(figure(5));
end
% pulisco variabili da riutilizzare per catena successiva
clear carico;
clear var_carico;
else
if ATTIVA == 1
ATTIVA = 0;
testo = Paragraph('Non sono presenti dati relativi al periodo temporale considerato.');
add(DT,testo);
add(DT,br);
if activeEN == 1
testo = Paragraph('No data available for the reference time period.');
add(DT_ENG,testo);
if m == 1
add(DT_ENG,br);
end
end
end
end
end
end
text = 'report_PrL function executed correctly';
fprintf(fileID,fmt,text);
fclose(fileID);
end